S15A1 Series Hydraulic Sequence Valve

S15A1 Series Hydraulic Sequence Valve
Details:
The S15A1 is a hydraulic sequence valve. It opens a secondary circuit when the primary circuit reaches a set pressure. No solenoids, no PLC, no wiring. Seven sizes available from 15 to 400 L/min. Adjustable opening pressure from 0 to 0.5 MPa. ISO 4401 mounting. OEM/ODM available. Brand: Onederful® Hydraulic.
Send Inquiry
Chat Now
Description
Send Inquiry

Shijiazhuang Laiye Import& Export Trading Co., Ltd. is one of the leading manufacturers and suppliers of s15a1 series hydraulic sequence valve in China, also supports customized service. If you're going to wholesale high quality s15a1 series hydraulic sequence valve made in China, welcome to get pricelist from our factory.

 

What a Sequence Valve Does

Some hydraulic circuits need order. Clamp first, then drill. Press first, then eject. Conveyor indexes, then the next part drops.

You can do this with a PLC and a solenoid valve. That works. But it adds cost, wiring, programming, and failure points.

Or you can use a sequence valve. It senses pressure. When the primary circuit reaches the set pressure, the valve opens. The secondary circuit gets oil. No PLC. No solenoid. No programming. Just pressure.

The S15A1 series hydraulic sequence valve is that valve.

Oil enters the inlet. A spring holds it closed. The spring preload sets the opening pressure. Below that pressure, the valve stays shut. Above it, the valve opens. Oil flows to the secondary circuit. Drop below the set point, the spring closes it again.

Turn the adjustment screw on top. Tighten it, the valve opens later. Loosen it, it opens sooner. That is how you set it.

 

Where You See These

Clamping and drilling. The clamp must close before the drill moves. That is the rule. The sequence valve enforces it. No wiring, no sensors, no control logic. Just pressure.

Presses. The main cylinder pushes down. It reaches full force. The valve opens. The ejector fires. The part comes out. One after another. Automatic.

Conveyor systems. One section moves. It reaches pressure. The next section moves. The sequence valve staggers the timing. Simple.

Multiple circuits, one pump. The pump feeds the highest priority circuit first. When that circuit reaches pressure, the valve shifts flow to the next. Everything gets oil, in order.

Test equipment. Need a specific sequence of pressure events? The sequence valve does it. No electronics. No programming. Just set the spring and go.

 

Specifications

Parameter Size 6 Size 8 Size 10 Size 15 Size 20 Size 25 Size 30
Nominal size 6 8 10 15 20 25 30
Max. pressure 31.5 MPa 31.5 MPa 31.5 MPa 31.5 MPa 31.5 MPa 31.5 MPa 31.5 MPa
Max. flow 15 L/min 30 L/min 40 L/min 120 L/min 200 L/min 300 L/min 400 L/min
Opening pressure (MPa) 0, 0.05, 0.15, 0.2, 0.3, 0.4, 0.5
Design number 0
Brand Onederful® Hydraulic
Custom OEM / ODM

 

How to Install and Set It

Mount it to a subplate. Standard ISO 4401 pattern.

The adjustment screw is on top. That is how you set the opening pressure.

Back the screw out, the valve opens earlier. Less spring force. Lower cracking pressure.

Screw it in, the valve opens later. More spring force. Higher cracking pressure.

There is no gauge on the valve itself. You need a pressure gauge on the inlet side to set it accurately. Slow pressure rise. Watch the gauge. The valve opens when the pressure hits the set point. That is your number.

Set it once. It stays. The locknut holds it. No drift. No creep.

 

How These Are Made

Casting

Raw castings come in. We check them for porosity. Bad ones get rejected.

Machining

We bore the body, drill the mounting holes, cut the sealing surfaces. The spool and seat get ground to size.

Cleaning

Everything goes through the wash. Chips and cutting fluid come off.

Assembly

Spool into body. Spring on top. Adjustment screw in place. Torque everything to spec.

Pressure Setting and Test

Every valve gets calibrated on the bench. We set the spring preload to the specified opening pressure. We cycle it a few times to make sure it cracks consistently. We check for leakage. The test data goes into the batch record.

Painting

Industrial paint on the body.

Packing

Cartons for small orders. Plywood cases for bulk.

Delivery

Sea, air, truck, railway, or express. You choose.

No shortcuts. No sampling. Every valve goes through the full routine.

production line

 

About the Company

We started in 1988. Over 200 people. Some have been here for twenty years. They know valves.

We are a manufacturer. We machine, assemble, and test in our own facility. Under one roof. That gives us control.

We ship over 10,000 containers a year. Twenty countries. Russia, Europe, the Middle East, South America, Southeast Asia. Agricultural equipment in Poland. Construction machines in Chile. Press builders in Thailand. Mining gear in South Africa.

We do custom work. OEM and ODM are routine. Drawings become products. Non-standard spools. Special settings. We have done many.

Minimum for custom is 10 pieces. Standard valves have no minimum.

Ten steps:

Casting inspection. Raw dimensions. Spool grinding. Body bore. Deburring and cleaning. Spring testing. Assembly torque. Pressure setting. Leak check. Final visual.

What you get:

12-month warranty from Bill of Lading. Technical support. Shipping options. Cartons or plywood cases.

 

FAQ

Q: What is the S15A1 series hydraulic sequence valve used for?

A: It opens a secondary circuit when the primary circuit reaches a set pressure. It controls order of operations.

Q: How is this different from a relief valve?

A: Relief valve limits pressure. It opens to tank. Sequence valve opens to another circuit. It directs flow somewhere useful.

Q: What is the pressure drop across the valve when it is fully open?

A: That depends on the flow rate and the size. Larger sizes have lower pressure drop at the same flow. If you are near the maximum flow rating for your size, the drop will be higher. We have test data for each size. Contact us if you need the curves.

Q: Do you offer factory-preset valves for specific pressures?

A: Yes. If you know your required opening pressure and do not want to adjust it on site, we can preset it at the factory. We set it on the test bench and lock the adjustment screw. Tell us the pressure when you order.

Q: How long does the adjustment screw stay in position once set?

A: It holds. There is a locknut on the adjustment screw. Tighten the locknut after you set the pressure. Vibration will not move it. If it moves anyway, the locknut was not tightened.

Hot Tags: s15a1 series hydraulic sequence valve, China s15a1 series hydraulic sequence valve, manufacturers, suppliers, factory, 2 spool hydraulic directional control valve, hydraulic monoblock solenoid directional control valve, hydraulic pilot operated directional control valve, pilot directional control valve, pilot operated dc valve, sectional valve